HT EXTENSOMETER
PMA-12

High-temperature extensometer PMA-12
High-precision high-temperature extensometer up to 1700° in air
General information
- The system is supplied without a cable for the encoder signal.
- The system also requires a TF amplifier (modulator, demodulator, signal amplifier). This is not included in the scope of delivery.
- A mandatory accessory for motorized control is: A slide-in unit that controls the approach of the probe fingers via the internal probe attachment mechanism.
Characteristics
- Version “V8” with higher sensitivity / lower nonlinearity (compared to “V7”).
- Easy operation thanks to swivel-slide suspension and feed motor for probe fingers.
- Quick test readiness.
- Uncomplicated positioning of the probe fingers.
- Output measuring length L0 is adjustable (from 6 to 50 mm), and the sample positioning mechanism is simple with a "probe finger is well positioned on sample" start-up indicator.
- Cuff rings for adjusting the measuring length L0 not required on the tensile test specimen.
| Scanning mechanism | Manual operation | Motor operation |
|---|---|---|
| Probe finger pressure force | 1-3 N (300g) adjustable, horizontal | 1-3 N (300g) adjustable, horizontal |
| Probe finger material | Al2O3, others optional | Al2O3, others optional |
| Probe finger position | Perpendicular to the sample longitudinal axis | Perpendicular to the sample longitudinal axis |
| Measuring length L0 | 6 – 50 mm, continuously adjustable by the customer | 6 – 50 mm, continuously adjustable by the customer |
| Permissible test vibration | max. 0,5 Hz (amplitude-dependent) | max. 0,5 Hz (amplitude-dependent) |
| Housing | Aluminum, anodized, stainless steel | Aluminum, anodized, stainless steel |
| Weight | Approx. 2 kg | Approx. 5 kg |
| Measuring system | |
|---|---|
| Measuring principle | Inductive Transformer (LVDT) |
| Measuring range (linear) | ± 10 mm, linear range |
| Resolution | < 0,1 μm |
| Supply voltage | 5 V |
| Carrier frequency | 10 kHz into 1 kΩ |
| Signal output | 37,5 mV/V/mm |
| max. nonlinearity | 0,1% of the full measuring range |
| Permissible measuring system Temperature | Max. 80 ° C |

Thanks to our many years of industry experience, we understand your specific requirements down to the last detail.
In modern testing technology, high-temperature and vacuum furnaces are indispensable: they simulate exact extreme conditions for demanding material tests.
They thus form the foundation for development, quality assurance and research in key industries such as aerospace, automotive, electronics and high-performance materials technology.